Skip to content
MedExams

General microbiology: sterilization, disinfection and biomedical waste

54 Kerala PSC Lab Technician Gr II practice questions on General microbiology: sterilization, disinfection and biomedical waste, part of Microbiology. The first 25 are below; the first 5 with answers and explanations (tap Show answer after you have chosen), the rest in Learn with a free account.

  1. Question 1 · Easy

    All of the following can be sterilized in a hot air oven EXCEPT:

    1. AGlass Petri dishes
    2. BRubber tubing
    3. CLiquid paraffin
    4. DDusting powder
    Show answer

    Answer: B · Rubber tubing

    Dry heat in a hot air oven suits materials that steam cannot penetrate or that moisture would spoil, such as glassware, oils and powders. Holding periods such as 160 °C for 1 to 2 hours are used, longer than for moist heat. Rubber perishes and plastics melt at these temperatures, so they are autoclaved or sterilized by other means. The oven should not be overloaded, so that hot air can circulate.

    • A: Glass withstands dry heat and comes out dry and ready to use.
    • C: Oils repel steam, so dry heat is the method of choice for liquid paraffin.
    • D: Steam cannot penetrate powders, so they are sterilized by dry heat.
  2. Question 2 · Easy

    Saturated steam at 15 lb/in² above atmospheric pressure has a temperature of about:

    1. A134 °C
    2. B100 °C
    3. C115 °C
    4. D121 °C
    Show answer

    Answer: D · 121 °C

    Raising the pressure raises the boiling point of water, so steam at 15 lb/in² (about 103 kPa) above atmospheric pressure reaches about 121 °C. Held for 15 minutes, this kills vegetative organisms and bacterial spores. Moist heat at this temperature coagulates microbial proteins far faster than dry heat at the same temperature.

    • A: 134 °C needs about 30 lb/in², as in high-speed pre-vacuum autoclaves.
    • B: 100 °C is the boiling point of water at normal atmospheric pressure.
    • C: 115 °C needs only about 10 lb/in² and is used for some sugar-containing media.
  3. Question 3 · Medium

    Gamma radiation is used to sterilize packed disposable plastic syringes because it:

    1. AActs only on the surface of the items
    2. BPenetrates the packing without heating it
    3. CWorks best on wet, unpacked items
    4. DLeaves a protective chemical residue
    Show answer

    Answer: B · Penetrates the packing without heating it

    Ionizing radiation from a cobalt-60 source passes through packaging and plastic and damages microbial DNA. The temperature hardly rises, so it is called cold sterilization and suits heat-sensitive items such as syringes, catheters and gloves. Items are irradiated already sealed in their final packs. Ultraviolet light, by contrast, penetrates poorly and acts only on exposed surfaces.

    • A: Surface-only action describes ultraviolet light, not gamma rays.
    • C: Items are irradiated dry and sealed in their final packs.
    • D: Gamma rays leave no residue; residue is a concern with ethylene oxide.
  4. Question 4 · Medium

    Which of these may still be present in serum after filtration through a 0.22 µm membrane filter?

    1. AViruses
    2. BStaphylococci
    3. CBacterial spores
    4. DEscherichia coli
    Show answer

    Answer: A · Viruses

    A 0.22 µm membrane retains bacteria, their spores and fungi, so it is used to sterilize heat-labile fluids such as serum, antibiotic solutions and sugar solutions. Most viruses are 20-300 nm across and pass through the pores. Mycoplasmas can also pass occasionally because they lack a rigid cell wall. The filter's integrity can be checked with a bubble-point test before use.

    • B: Staphylococci are about 1 µm across and are retained.
    • C: Bacterial spores are about 1 µm across and are retained.
    • D: E. coli rods are far larger than 0.22 µm pores and are retained.
  5. Question 5 · Medium

    A disinfectant has a Rideal-Walker coefficient of 4. This means it:

    1. AIs four times as active as phenol
    2. BKills Salmonella in 4 minutes
    3. CIs four times as toxic as phenol
    4. DWorks only at a 1 in 4 dilution
    Show answer

    Answer: A · Is four times as active as phenol

    In the Rideal-Walker test, dilutions of the disinfectant and of phenol act on Salmonella Typhi, and samples are subcultured at fixed intervals. The coefficient is the dilution of the disinfectant that kills in a given time divided by the dilution of phenol that does the same. A coefficient of 4 means the disinfectant can be diluted four times more than phenol and still kill. The test has no organic matter, which the Chick-Martin test adds to mimic real use.

    • B: The coefficient is a ratio of dilutions, not a killing time.
    • C: The test measures killing power, not toxicity to tissues.
    • D: The coefficient compares activity with phenol; it is not a working dilution.
  6. Question 6 · Hard

    After an autoclave run of discarded cultures, the indicator tape on the bags has changed colour, but the Geobacillus stearothermophilus spore strip from the centre of the load shows growth. The most likely cause is:

    1. ATape stuck on the outside of the bags
    2. BHolding time set longer than 15 minutes
    3. CStrip incubated at 37 °C, not 56 °C
    4. DAir trapped in a tightly packed load

    Answer and explanation in LearnFree account

  7. Question 7 · Hard

    To prepare 1 litre of 1% available chlorine for cleaning blood spills, how much bleaching powder containing 25% available chlorine is needed?

    1. A10 g
    2. B2.5 g
    3. C40 g
    4. D4 g

    Answer and explanation in LearnFree account

  8. Question 8 · Medium

    What does the daily Bowie-Dick test on a pre-vacuum autoclave check?

    1. AAccuracy of the pressure gauge
    2. BKilling of Geobacillus spores
    3. CDryness of the load at the end
    4. DAir removal and steam penetration

    Answer and explanation in LearnFree account

  9. Question 9 · Easy

    Tyndallisation steams a medium at 100 °C for 20 minutes:

    1. AOnce, followed by quick cooling
    2. BOn three successive days
    3. CTwice on the same day
    4. DDaily for one full week

    Answer and explanation in LearnFree account

  10. Question 10 · Easy

    Which method is used to sterilize Lowenstein-Jensen medium?

    1. AAutoclaving
    2. BTyndallisation
    3. CInspissation
    4. DMembrane filtration

    Answer and explanation in LearnFree account

  11. Question 11 · Easy

    Under the Bio-Medical Waste Management Rules 2016, used needles and scalpel blades are discarded in a:

    1. ACardboard box with blue marking
    2. BRed non-chlorinated plastic bag
    3. CYellow non-chlorinated plastic bag
    4. DWhite translucent puncture-proof container

    Answer and explanation in LearnFree account

  12. Question 12 · Hard

    A laboratory is sorting its waste under the Bio-Medical Waste Management Rules 2016. Which item is matched with the correct container?

    1. ABroken contaminated slides – blue box
    2. BNeedles from a needle cutter – red bag
    3. CUsed examination gloves – blue box
    4. DPlastic culture plates – white container

    Answer and explanation in LearnFree account

  13. Question 13 · Medium

    Ultraviolet light can disinfect the work surface of a safety cabinet but cannot sterilise wrapped items, because it:

    1. AHeats the items
    2. BKills only vegetative cells
    3. CPenetrates poorly
    4. DLeaves toxic residues

    Answer and explanation in LearnFree account

  14. Question 14 · Easy

    In the holder method of pasteurising milk, the milk is heated at:

    1. A100 °C for 20 minutes
    2. B121 °C for 15 minutes
    3. C63 °C for 30 minutes
    4. D72 °C for 15-20 seconds

    Answer and explanation in LearnFree account

  15. Question 15 · Easy

    What material are Chamberland candle filters made of?

    1. ADiatomaceous earth
    2. BUnglazed porcelain
    3. CSintered glass
    4. DAsbestos pads

    Answer and explanation in LearnFree account

  16. Question 16 · Medium

    Moist heat sterilises at a lower temperature than dry heat mainly because steam:

    1. ARemoves all water from the bacterial cell
    2. BReaches a higher temperature than hot air
    3. CKills bacteria by oxidising their contents
    4. DGives up latent heat and coagulates proteins

    Answer and explanation in LearnFree account

  17. Question 17 · Easy

    Which gas is used to sterilise heat-sensitive items such as heart-lung machines and plastic catheters?

    1. AFormaldehyde
    2. BNitrous oxide
    3. CCarbon dioxide
    4. DEthylene oxide

    Answer and explanation in LearnFree account

  18. Question 18 · Hard

    A technician autoclaves 500 mL flasks of broth at 121 °C for 15 minutes. The caps are loosened, the load is not crowded, and the air was let out before the valve was closed. To save time, she opens the release valve as soon as the timer ends, while the gauge still reads 15 lb/in². Several flasks boil over. The most likely cause is:

    1. ASudden pressure drop over superheated liquid
    2. BAir left in the chamber during the cycle
    3. CCaps too loose on the flasks
    4. DHolding time too long for the volume

    Answer and explanation in LearnFree account

  19. Question 19 · Medium

    Under the BMW Rules 2016, discarded culture plates and stock cultures from a microbiology laboratory are:

    1. APre-treated on site, then sent in yellow bags
    2. BSent untreated in yellow bags
    3. CPre-treated on site, then sent in red bags
    4. DSent untreated in red bags for recycling

    Answer and explanation in LearnFree account

  20. Question 20 · Easy

    Contaminated recyclable plastics such as gloves, IV sets and urine bags are collected, under the BMW Rules 2016, in a:

    1. AWhite puncture-proof container
    2. BRed bag
    3. CBlue cardboard box
    4. DYellow bag

    Answer and explanation in LearnFree account

  21. Question 21 · Medium

    Spore strips of which organism are used to monitor ethylene oxide sterilisation?

    1. AClostridium tetani
    2. BGeobacillus stearothermophilus
    3. CBacillus pumilus
    4. DBacillus atrophaeus

    Answer and explanation in LearnFree account

  22. Question 22 · Medium

    Which test checks whether a disinfectant already in use on a ward is still killing bacteria, by culturing a sample of it?

    1. AKelsey-Sykes test
    2. BIn-use test
    3. CChick-Martin test
    4. DRideal-Walker test

    Answer and explanation in LearnFree account

  23. Question 23 · Hard

    A phlebotomy area produces blood-soaked cotton swabs, used plastic syringes whose needles were cut off with a needle cutter, and the cut needles. Under the BMW Rules 2016, which segregation is correct?

    1. ACotton yellow; syringes yellow; needles white
    2. BCotton red; syringes red; needles blue
    3. CCotton yellow; syringes red; needles blue
    4. DCotton yellow; syringes red; needles white

    Answer and explanation in LearnFree account

  24. Question 24 · Medium

    Cetrimide, a quaternary ammonium disinfectant, loses much of its activity when mixed with:

    1. ASoap
    2. BEthanol
    3. CDistilled water
    4. DChlorhexidine

    Answer and explanation in LearnFree account

  25. Question 25 · Medium

    A large blood spill is flooded with 1% hypochlorite without first soaking up the blood, and later cultures from the floor still grow bacteria. The likely reason is that hypochlorite:

    1. AIs inactivated by organic matter
    2. BNeeds heating before it acts
    3. CDoes not act on Gram-negative bacteria
    4. DIs neutralised by floor soap residues

    Answer and explanation in LearnFree account

29 more General microbiology: sterilization, disinfection and biomedical waste questions

Answer them one by one, keep your score and see your weak topics in Learn. Signed-out visitors try 25 per exam; sign in with Google to see them all.

Study Microbiology