Question 1 · Hard
A red cell unit was warmed in an unapproved device before a rapid transfusion. The patient then has red urine and plasma hemoglobin is raised. The clerical check, repeat ABO/Rh and DAT are all as expected (DAT negative). The most likely cause is:
- AAn ABO-incompatible acute hemolytic reaction
- BA febrile nonhemolytic transfusion reaction
- CHeat damage to the red cells (nonimmune hemolysis)
- DA delayed hemolytic reaction from anti-Jka
Show answerHide answer
Answer: C · Heat damage to the red cells (nonimmune hemolysis)
Overheating destroys red cells before they enter the patient, causing hemoglobinemia and hemoglobinuria without an antibody. A negative DAT, a correct clerical check and matching ABO types point away from immune hemolysis. Other nonimmune causes include freezing, hypotonic or dextrose solutions in the line, and pressure from small needles or pumps. Only approved, monitored blood warmers should be used.
- A: An ABO-incompatible reaction would show an error in the clerical check or ABO types, usually with a positive DAT.
- B: A febrile reaction causes fever without hemoglobinuria.
- D: A delayed reaction appears days later, with a positive DAT and a new antibody.