Question 1 · Hard
A patient's screen and autocontrol are negative. One of four units is 2+ incompatible in the AHG crossmatch; the others are compatible. Which test should be done first?
- AA slow infusion of the unit to watch for reactions
- BAn eluate from the patient's red cells
- CA DAT on the incompatible donor unit's cells
- DA repeat screen incubated at 4 °C
Show answerHide answer
Answer: C · A DAT on the incompatible donor unit's cells
If the donor's own red cells are coated with IgG, they react with anti-human globulin in any crossmatch, whatever the patient's plasma contains. A positive DAT on a segment from the unit confirms this; the unit is not used and the supplier is told. If the donor DAT is negative, an antibody to a low-prevalence antigen on that unit is the next explanation. Either way, another compatible unit is chosen.
- A: An incompatible unit should not be transfused.
- B: The patient's autocontrol is negative, so an eluate is not useful.
- D: Clinically significant antibodies are not found at 4 °C.