Question 1 · Hard
A 5-week-old girl has had paroxysmal cough for 10 days, with episodes of apnea and cyanosis but no fever. Her mother has been coughing for a month. WBC 34.0 x 10^3/µL [34.0 x 10^9/L] with 76% lymphocytes. A nasopharyngeal specimen is collected with a calcium alginate-tipped swab, placed in a dry sterile tube, refrigerated and tested within 24 hours by a Bordetella pertussis PCR. The result is invalid because the internal amplification control fails, and repeat testing of the same specimen gives the same result. What is the most likely cause?
- AInhibitors from the calcium alginate swab
- BRefrigeration of the specimen in transit
- CInterference from recent pertussis vaccine
- DToo few bacilli this late in the illness
Show answerHide answer
Answer: A · Inhibitors from the calcium alginate swab
An invalid result with a failed internal amplification control means that something in the specimen blocked the PCR. Calcium alginate swabs release substances that inhibit PCR, so Dacron (polyester), rayon or nylon flocked swabs are used for Bordetella PCR. The infant's paroxysms, apnea and marked lymphocytosis, with a coughing household contact, strongly suggest pertussis. At 10 days of cough the bacterial DNA load is high, refrigeration is acceptable for PCR, and a 5-week-old has not yet had the first DTaP dose, usually given at 2 months. A new nasopharyngeal swab with an acceptable tip should be collected at once.
- B: Refrigeration is acceptable for PCR specimens and does not inhibit amplification.
- C: A 5-week-old has not yet received DTaP, which is usually first given at 2 months.
- D: Ten days into the cough the load is high, and a low load would not make the internal control fail.